Week #3 Spindle - June 13/2023
File Version: 5.1
Material - 4340 Steel Annealed was used
Error Message: A large displacement error message occurred. Clicked no to continue with the study.
Fixtures
The fixture locations are shown in the screenshot below.
Mesh
Loading Case 1
There is a 2096.57y force from the inner hub to the spindle. The loading case and results are shown below.
Loading 2
Outer Hub to the spindle is -6872y, 74.34z
The inner Hub to Spindle is -1080.4 (OMITTED), 9033y, 1006z
Loading Case 3 (screenshots in order)
Please correct if the location of the x-direction load is incorrect,
Outer Hub to spindle: 759x, 4834y, -52.28z
Inner Hub to Spindle: -3314y, 812z
Loading Case 4
Outer Hub to Spindle: -8786y, 95z
Inner Hub to Spindle: -1381x(OMMIT), 11549y, -1476z
(Outter hub locations corrected / screen shots accidentally show inner hub)
Loading Case 5
Outer hub to spindle: 971x, 6180y, -66z
Inner hub to Spindle: -4237y, -904z
Recommendations
TBD