UV Cutoff Validation Notes [MSXV]
10-08-2023
Power supplied to the PD_12 and the BAT_IN
PD_12 supply set the 12V
Checked the voltage at PD_12, and it is correctly 12V
BAT_IN set to voltages ranging from 9V to 15V
When first testing and setting the voltage to >12V, the comparator output measured around 12V. However, when turned down to <11V the output still remained high.
Restarting the test, both states produced a 0V output at the comparator.
Afterward, restarted the test but the output of the comparator outputted a voltage less than but proportional to the BAT_IN. For example, with the power supply set to 9V the comparator output was around 6V, with 13V around 7.5V and so on.
Next steps: the validation plan makes sense according to a schematic, will check the physical hardware.
11-08-2023
Power and ground for PD_12 and BAT_IN are not shorted
Checked the respective voltage rails, all seem to be shorted properly
Re-validated and the wires connecting the board to the power supply are faulty
Validating for HIGH comparator output:
BAT_IN set to 14V and the comparator outputted 12V
Validating for LOW comparator output:
BAT_IN set to 7V and the comparator outputted 0V