Notes:

-Changed the design to improve its strength and manufacturability.

-May need to add counterbores for the screw holes.

-Please verify if my fixtures are valid.

Material: 6061-T6 Aluminum, Yield Strength: 2.750E8 N/m^2.

Fixtures:

On flat faces to restrict planar movement

Interactions:

These virtual walls represent where the mount contacts the floor and screws respectively

Loading:

1.3 kN directed 6.9 degrees below the horizontal but multiplied by 2 as a safety factor

Mesh:

Results:

Note: Just for reference, the force is directed to the left in this image.

Next Steps: Can probably cut off chunks of material in order to reduce weight