Below will be the list of general procedures along with the equipment required for each testing standard we will attempt to do for testing each bulkhead.
Please note that although each standard says to test 5 specimens each, we may not have 10 specimens of each bulkhead so we may have to do less.
ASTM C393
Test Specimen Requirements
Length x Width x Depth - 200 mm x 75 mm x Thickness of Sandwich Construction
Make sure to test at least five specimens per test condition.
Equipment Needed:
Micrometers and/or callipers
Deflectometer/Deflection gages (ONLY if the UTM can’t measure the displacement)
Conditioning Chamber
Environmental Testing Chamber
3-point bend fixture
UTM
Procedures:
Condition the specimen in a chamber if the test environment is not the same as a conditioned environment.
Measure the length, width and thickness at three places in the specimen.
Place the specimen into the test fixture as shown in the equipment and apparatus section.
Attach the deflection transducer (if we choose to use one).
Apply a compressive force to the specimen until failure or until a deflection equal to the thickness is reached.
Variable | Quantity |
---|---|
Load rate | 6mm/min |
Failure occurence | 3-6 minutes |
Support bar separation |
ASTM D3039
Test Specimen Requirements
Test at least 5 specimens
Equipment Needed:
3 Force Indicator
Grips
Strain Indicating Device
Extensometer
Strain Gauge
Tabs( We should probably fabricate our own tabs)
UTM
Procedures:
Measure the specimen in 3 places and report average thickness and width as well as average area.
Place the specimen into the grips of the testing machine
Apply the force until failure occurs
Variable | Quantity |
Failure occurence | 1 to 10 min |
Head displacement | 2mm/min |