Below are the general procedures for each test.

ASTM D903

  • Prep the specimen.

  • Precondition the test specimen.

  • Test the specimen as soon as possible after conditioning

  • Place the specimen in the test apparatus

  • Wait until failure

Variable

Quantity

Grip Separation

About 1 Inch

Stripping angle

180 degrees.

ASTM D950

  • Put the specimen in the jig that is in the vise of the machine so the specimen butts squarely against the end of the jig.

  • Rest the impact head against the specimen and adjust the jig so the head fits squarely against the impact face.

  • Raise the impact head and release the safety catch.

  • We will then note the impact energy absorbed.

ASTM D5868

  • Apply the adhesive in accordance with the adhesive suppliers recommendations. 

  • Adhesive Cure—Cure the adhesive at room temperature or elevated temperature using prescribed conditions determined by the adhesive supplier.

  • Condition the test specimens

  • Place specimens in UTM

  • Wait for failure

Variable

Quantity

Grip Separation

75mm

load rate

13mm/min