Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Below are the general procedures and equipment for each test. testing standard required for testing adhesives

ASTM D903

Equipment:

  • Micrometers and/or callipers

  • Deflectometer/Deflection gages (ONLY if the UTM can’t measure the displacement)

  • Conditioning Chamber

  • Environmental Testing Chamber

  • 3-point bend fixture

  • UTM

Procedures:

  • Prep the specimen.

  • Precondition the test specimen.

  • Test the specimen as soon as possible after conditioning

  • Place the specimen in the test apparatus

  • Wait until failure

Variable

Quantity

Grip Separation

About 1 Inch

Stripping angle

180 degrees.

ASTM D950

Equipment:

  • 3 Force Indicator

  • Grips

  • Strain Indicating Device

  • Extensometer

  • Strain Gauge

  • Tabs( We should probably fabricate our own tabs)

  • UTM

Procedures:

  • Put the specimen in the jig that is in the vise of the machine so the specimen butts squarely against the end of the jig.

  • Rest the impact head against the specimen and adjust the jig so the head fits squarely against the impact face.

  • Raise the impact head and release the safety catch.

  • We will then note the impact energy absorbed.

ASTM D5868

Equipment:

  • Compression fixture

  • Strain-indicating device

  • Special alignment jig

  • Bonded Resistance Strain Gauges

  • Emery cloth

  • I believe UTM

  • Conditioning chamber

  • Environmental test chamber

  • Extensometer

Procedures:

  • Apply the adhesive in accordance with the adhesive suppliers recommendations. 

  • Adhesive Cure—Cure the adhesive at room temperature or elevated temperature using prescribed conditions determined by the adhesive supplier.

  • Condition the test specimens

  • Place specimens in UTM

  • Wait for failure

...