Regulator and Connector Test Board

Purpose

  • Test out different switching regulators, determine efficiency, voltage ripple, decoupling capacitance
  • Test out different wire-to-board headers for current capacity and repeated use
  • Test different board-to-board headers for current capacity and repeated use
  • Test quality of silkscreen, solder mask, current capacity of traces

Results

  • Switching regulators were tested from 10mA to 1A, up to 700mVpp ripple was observed compared to up to 500mVpp ripple from LDOs on MSXI (Measurement tools may have some errors)

Schematic