The Upper Upright Bearing Cap
Loading
Loading Case #1:
Upright to UCA | -3299.679523 | -115.1178968 | 52.35353565 | 0 | 0 | 0 |
Loading Case #2:
Upright to UCA | 5289.283482 | 184.5304023 | 493.6893625 | 0 | 0 | 0 |
Loading Case #3:
Upright to UCA | -8504.324391 | -296.6954611 | 369.6017313 | 0 | 0 | 0 |
Loading Case #4:
Upright to UCA | 6762.228426 | 235.9179152 | -533.8395702 | 0 | 0 | 0 |
Loading Case #5:
Upright to UCA | -10872.67222 | -379.3214308 | -346.9078363 | 0 | 0 | 0 |
Fixtures
Mesh Refinement
Mesh Convergence & Results
Case #2: Forwards Left
Node Size | Max Stress (Pa) | Location |
---|---|---|
2 mm | 2.447e+06 | |
1.75 mm | 2.545e+06 | |
1.5 mm | ||
1.25 mm | ||
1 mm |
Case #4: Forwards Right
Node Size | Max Stress (Pa) | Location |
---|---|---|
Recommendations
The bearing housing cap passed both extreme cases, with the lowest safety factor (3.59) occurring in case #4.