BMS Carrier
BMS1: Killswitch works | flash smoke_bms latch the killswitch, should log an interrupt on minicom with the correct state unlatch the killswitch, should log again shake the killswitch and repeat a few times to ensure connections are good
|
BMS2: 1 AFE Vsense works | in the battery mockup, connect one AFE’s cell power wires flash smoke_afes and set it to just one AFE observe voltages on minicom verify at least one cell voltage with a multimeter
|
BMS3: All AFE Vsense works | |
BMS4: 1 AFE temp sense works | |
BMS5: All AFE temp sense works | |
BMS6: Cell balancing works | setup for BMS3 but enable cell balancing in the smoke test note the difference between the highest and lowest voltages for each AFE wait 5 minutes verify that the difference between the highest and lowest voltages has decreased in magnitude
|
BMS7: Current sense works | |
BMS8: Battery fans work | |
BMS9: Relays work | flash smoke_bms by default the relays should be enabled when powering on the board with the code flashed, an audible click should be heard from the relays closing verify continuity on the relays with a multimeter (the two leads on the top of each relay should be continuous)
|
Charger
C1: MCP2515 works | |
C2: Connection sense works | |
C3: Control pilot works | |
C4: Elcon comms works | |
Solar
SO1: Front vs. rear identification works | |
SO2: 1 MPPT SPI works | |
SO3: All MPPT SPI works | |
SO4: Array temp sense works | |
SO5: 1 MPPT MCP3427 works | |
SO6: All MPPT MCP3427 works | |
SO7: Isense MCP3427 works | |
SO8: Relay works | |