2.5.1CapacityCruiser class vehicles have no total mass limitationsHigh
2.5.3SpecificationTeams must submit detailed specification of intended cellsHigh
2.5.8Operating RangeCells must never be operated outside of voltage, current and temperature ranges supplied by the manufacturerHigh
2.5.9Charging System

Any AC input charging system must meet following requirements

● the charger must be used with a residual current device

● the charger must be either permanently connected to the energy storage system, or connect to the energy storage system using an appropriate connector

● the output of the charger must be electrically isolated from the ac input

● the charger must stop charging automatically when the energy storage system is full or if a fault occurs.

High
2.5.13MountingEnergy storage packs must remain restrained in a 20g accelerationHigh
2.5.14Spill Protection

Spill-proof barrier must be present between energy storage system and occupants. If energy storage system is capable of spilling

High
2.5.15VentilationVentilation must carry any gases to the exterior of the vehicle. If energy storage system is capable of emitting gases.High
2.5.17Tamper-Evident

Energy storage packs must be constructed to be sealed using tamper-evident plastic seals similar to 3x100mm plastic cable ties.

Said ties cannot be removed after scrutineer has been completed

High
2.28.5High Voltage SymbolHigh-voltage energy storage packs must be marked with the high-voltage symbolHigh
2.28.6HV Symbol VisibilityHV Symbol must be visible on any enclosure or barrier that can be access without tools, if HV parts are exposedHigh
2.28.10Fuse

Energy storage packs must be protected by a fuse or circuit breaker to interrupt the short-circuit fault current of the pack

Must be mounted in or on the energy pack

High
2.5.7Storage SystemMaximum of 2 packs for entirety of energy storage systemMed
2.5.10Other Batteries 1

Batteries used only to

● power a real time clock when the solar car is turned off; or

● retain data when the solar car is turned off; or

● power wireless tyre pressure monitors

are not considered part of the energy storage system (max 2.0Wh)

Med
2.5.11Other Batteries 2Batteries used in handheld radios, cameras, mobile telephones or wristwatches carried by the driver are not considered part of the energy storage systemMed
2.5.12CapacitorsCapacitors are not considered part of the energy storage system if capacity is less than 10Wh. Such capacitors must discharge to less than 60V within 5 secondsMed
2.5.16Removable Packs

● Energy storage system must remain in a safe state when disconnected

● Team must provide a lockable box for storing the energy storage packs

Med
2.28.1Double InsulationDouble protection from high-voltage parts, such as enclosures or barriersMedCommon Sense
2.28.3HV Protection Against Direct Contact

HV parts outside of driver, passenger and luggage compartment must be designed to exclude fingers (Ingress Protection rating IPXXB).

Test for IPXXD

A probe is required. The probe consists of an insulated handle about 100 mm long and about 10 mm in diameter which ends in an insulated sphere (stop face) of 35 ± 0.2 mm diameter. On the opposite side of the sphere is a metal rod 100 mm long and 1
+0.05-0 mm in diameter. The live parts in the enclosure are connected together with wire and connected in series with a lamp, a suitable ELV supply and the 1mm diameter metal rod of the probe.

The tip of the metal rod is pressed gently against the opening. If the rod goes in there must be adequate clearance between the rod and the live parts i.e. the lamp should not light up. Tests must be made with the rod in all possible positions. The lamp must not light up.

The full diameter of the insulated sphere (stop face) must not be able to pass through the opening.

Med
2.5.2Uncommon CellTeams must contact organizers if other cell chemistry are usedLowWe use Li-ion cells
2.5.4Nominal Mass EndorsementSpecified and endorsed by manufacturerLowWe have no mass capacity
2.5.5Nominal Mass Conflicting SpecsOrganizers will determine nominal mass if conflicting or unclear values are providedLow
2.5.6Sum Nominal MassSum off nominal masses must not be more than allowable massLow