Feb 26 2021

Jess

BMS CARRIER

  • testing with two AFEs, not one in the middle

  • initially wasn't working, got just 0xff for data and PEC error

  • plugged just far left IsoSPI to carrier, then put config back to normal, then it worked fine

  • looking at thermistor readings only lists 12/AFE, changed to 32 (from schematics)

    • there's some significant reworking to be done around thermistor readings

    • seems like we already just cycle through all aux readings before proceeding, maybe can just bump to 32 different reads

  • I spent most of my time looking at code / data sheets, no real new testing

Things for other firmware members to do

  • validate the controller boards sitting on elec bench (check leds, check CAN)

  • set up what boards we currently have, make sure power sequencing works