This page will document all the changes for the second revision of solar sense → changes found from validation and assembly:

  • relay footprint is wrong → increase the through hole size, pad size and distance between everything so it actually mates
  • have a pin on the controller board get a high or low if connected to the right jumper config for 5 vs 6 mppt board
  • none of the vias tented?? maybe manufacturing issue (this was not jlc) but double check pcb
  • move C32 north so 12V isnt shorted to ground 😞
  • switch mosi and clock and fix miso silk (says mso)
  • reconfigure relay driver for low side output for current sinking IC
  • indicator LED for 12V
  • move the I2C pullup resistors to be near the controller board, not near the first mppt
  • Add a fan control IC for solar fan (meant to help cool nomuras inside enclosure) controlled by onboard thermistor and powered off of solar (will be depopped for 6th solar board)