Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Current »

This smoke test is to test enabling a load and taking the input from current sense.

After populating U5 and fixing U12, I was able to drive the lights driver board + LED board and use the current controlled pot to vary the draw and collect data points from IS pin on U5. The following table summarizes those recordings.

Reading on Minicom

Voltage at IS pin (V)

~Current Draw (A) (on Power Supply so is estimate)

20-38

0.025

0.015

108-129

0.095

0.035

170-193

0.147

0.060

283-302

0.237

0.095

316-351

0.268

0.110

441-480

0.369

0.145

551-628

0.478

0.195

650-750

0.553

0.225

722-1185

0.774

0.310

924-1727

1.085

0.450

1205-1687

1.177

0.500

  • No labels