Model Version: 8.0
Material: AISI 4130 steel, annealed at 865C
Validation: June 14th 2023 -
Screw holes fixed axially and radially
Bearing housing fixed radially
Bearing Housing virtual wall on both sides
Fx & Fy:
Fx and Fy are first combined into a single force using trigonometry to determine the magnitude and angle the force acts at, called Fxy
Smile Khatri has a good example in their UCA report from the week of may 29th
Fxy applied at the inside of the UCA Bearing Adapter part, normal to a plane that is at the angle of the applied force
The force is only applied to one half of the cylindrical face
Fz:
Applied normal to the UCA Bearing Adapter part, on the side in which the direction of the force is acting
Loading Cases
Case
Fx
Fy
Fz
Fxy
Fxy plane angle (deg)
1
-3299.679523
-115.1178968
52.35353565
3301.686983
88.002
2
5289.283482
184.5304023
493.6893625
5292.501414
3
-8504.324391
-296.6954611
369.6017313
8509.498313
4
6762.228426
235.9179152
-533.8395702
6766.342479
5
-10872.67222
-379.3214308
-346.9078363
10879.28701