titleFigures

Figure 1: No mass, Side 60 Wall

Figure 2: No mass, Top 60 Wall

Figure 3: Top 60 Wall, odd result

Figure 4: Battery box only, Side 60 Wall

Figure 5: Battery box only, Top 60 Wall

Figure 6: 17 Tube configuration

Figure 7: results from figure 6, side 60 wall

Figure 8: Iteration 7 results

Figure 9: Front 30 wall with 17 tube distribution with 250mm pinball radius

Expand
titleFrom Kevin's suggestion, we will be seeing if changing mass distribution wrt tube selection changes anything

All mass distributed on all tubes vs. Specific mass distributed on respective tubes

Front 30 Wall - All mass on all tubes

Max = 359.41MPa

Image Modified

Corresponding Mass Setup

...

Image Added

Front 30 - Realistic Mass

Max: 305.73MPa

Image Modified

Conclusion: not a significant effect, 50MPa by drastically altering the weight distribution; but an effect nonetheless

...

Note, not sure how Tommy got the picture below (from chassis FEA advisors meeting)

...