Expand | ||
---|---|---|
| ||
Other things we need:
Spreadsheet with component specs:
View file | ||
---|---|---|
|
Inductor: AGP4233-473ME (100khz) or -683 (50khz), larger
Lower frequency → higher efficiency (less switching loss), more mass (larger coils)
Other simpler components in spreadsheet, seem feasible.
~4 mOhm at 7.5V
Current Progress:
MPPT with output regulation:
View file | ||
---|---|---|
|
updated preadsheet with boost converter specs:
View file | ||
---|---|---|
|
To investigate: not using a multiplier
Potentially via output current sensing?
Battery should keep (in a short timeframe) stable voltage, so sensing the output current would give us a proxy for power
Next steps:
Create schematic
Expand | ||
---|---|---|
| ||
Other pages to be aware of in regards to Nomura MPPT Testing: Nomura SPI Testing Nov 19/20 2019 Nomura MPPT - Documentation for Nomura MPPT and SPV1020 IC MPPT Testing - Testing done in 2017 by Taiping Solar Collector System Analysis Workterm Report - Work term report about Solar (including MPPTs) Further Nomura Testing - Solar panel and MPPT testing in 2020 by Micah Nomura Ideal Diodes - Includes some ideal diode testing results |