Next steps: the validation plan makes sense according to a schematic, will check the physical hardware.

11-08-2023

  • Power and ground for PD_12 and BAT_IN are not shorted

  • Checked the respective voltage rails, all seem to be shorted properly

  • Re-validated and the wires connecting the board to the power supply are faulty

  • Validating for HIGH comparator output:

    • BAT_IN set to 14V and the comparator outputted 12V

  • Validating for LOW comparator output:

    • BAT_IN set to 7V and the comparator outputted 0V