ASTM C393_Standard Test Method for Shear Strength

Expand
titleTest Specimen and Geometry
  • Specimen has rectangular in cross-section

  • Length x Width x Depth - 200 mm x 75 mm x Thickness of Sandwich Construction

  • Make sure to test at least five specimens per test condition unless you are confident that the results obtained are valid through the use of fewer specimens.

Expand
titleEquipment and Apparatus:
  •  Equipment: ball-interfaced and anvil interface micrometer, deflectometer, conditioning chamber, environmental test chamber are recommended but not required.

  • Apparatus: The machine will have a stationary and movable head, the machine should be able to indicate the total force being carried by the test specimen, it will either be a 3- or 4-point bend test. Below is what they used

Image RemovedImage Added
Expand
titleProcedure:
  • Test at least five specimens.

  • Condition the specimen in a chamber if the test environment is not the same as a conditioned environment.

  •   Measure the length, width and thickness at three places in the specimen.

  • Place the specimeninto the test fixture and align the fixture so the longitudinal axis of the specimen is perpendicular (within 1 degree) to the longitudinal axes of the loading bars, the bars must also be parallel (within 1 degree) to the plane of the specimen facings.

  •  Attach the deflection transducer.

  • Apply a compressive force to the specimen until failure or until a deflection equal to the thickness is reached.

  • It was noted that the speed of testing should be around 6mm/min. 

  • Failure should occur at 3-6 minutes.

...

ASTM D3039_Standard Test Methods for Tensile Properties

Expand
titleTest Specimen and Geometry:
Expand
titleEquipment and Apparatus:
  • 3 Force Indicator, Grips, Strain-Indicating Device, Strain transducer, Extensometer, Strain Gauge, End Tabs. 

  • Tensile Testing machine with a stationary head and a movable head. 

Image Added
Expand
titleProcedure:
  • Test at least 5 specimens

  • Measure the specimen in 3 places and report average thickness and width as well as average area. 

  • The speed of testing should be able to have a nearly constant strain rate and it will produce failure within 1 to 10 min. 

...

 ASTM D3410_Standard Test Method for Compressive Properties of Polymer Matric Composite Materials

Expand
titleGeometry:Test Specimen and Geometry
  • Sampling—Test at least five specimens per test condition unless valid results can be gained through the use of fewer specimens

  • The test specimen will have a constant rectangular cross section with a specimen width variation of no more than 1% and a specimen thickness variation of no more than 2%, the tables below give more detail.

  • Below is an equation to get the recommended test thickness

Expand
titleEquipment and Apparatus:
  • Equipment required:

    • Micrometers/calipers

    • Strain-Indicating Device

    • Bonded Resistance Strain Gauges

    • Emery cloth

    • Special Alignment Jig (pictured below)

  • Compression Testing Fixture(pictured below are schematics and the actual fixture)

Image RemovedImage Added

Image RemovedImage Removed

Image AddedImage Added

  • Apparatus:

    • There will be a force indicator

    • The machine will have two loading heads. 

^^^I don’t exactly know what this means (interpret pls)

  • The drive mechanism will be able to give a controlled displacement rate with respect to the stationary head. 

  • If the atmosphere conditions suck use a conditioning chamber and an environmental test chamber.

  • If the material is super stiff use an extensometer. 

...

Expand
titleGeometry:
  • Will be the same as the above standard along with the following:

Image RemovedImage Added
Expand
titleEquipment and Apparatus:
  • Same as the above standard.

...

ASTM D903_Standard Test Method for Peel or Stripping Strength of Adhesive Bonds

Expand
titleTest Specimen and Geometry:
  •   The above is the diagram of the geometry

  • Test at least 10 test specimens for each adhesive.

  • Discard specimens that give out of line test results due to obvious flaws and then retest.

Expand
titleEquipment and Apparatus:
  • Apart from the testing apparatus, the only equipment needed is a conditioning room/desiccators

  • The following is a picture of the testing apparatus:

...