Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

View file
nameEA E120HP-EN.pdf

View file
nameAdhesive Testing Data.xls

Adhesive test results are based on material testing procedures outlined here:
Material Testing for Adhesives

Load rate 1 mmm/min too fastused used for Universal Testing Machine (UTM) was 0.5 mm/min.

Raw Data

Refer to the file “Adhesive Testing Data.xls” for the raw data outputted from the Universal Testing Machine

Processed Data

Refer to the file “EA E120 HP-EN.pdf” for the adhesive’s technical data sheet.

Table #1: Max shear stress of each test specimen

Specimen

Max Shear Stress (MPa)

None 1

3.227076

None 2

15.00324693

None 3

3.51152

Degrease 1

7.364299

Degrease 2

1.401875

Degrease 3

3.46305

Abrade 1

5.961373

Abrade 2

4.618917913

Abrade 3

9.213191

Table #2: Average max shear stress of each surface preparation technique

Surface Preparation

Average Max Shear Stress (MPa)

None

7.247280977

Degrease

4.076408

Abrasion

6.597827304

Graphs:

...