Height from H Point (mm)

Minimum Recommended Width (mm)

220

384

318

471

534

545 *(see note below)

[6]

  • Not from source 6 - but from in house testing and CAD analysis

Shoulder Belt Passthroughs:

  • Shoulder Belt Passthroughs should be just above the occupants shoulders and must accommodate ASC and WSC regulations as well as anthropometric data below

  • Note: If you are designing for a different set of occupants (e.g. 5th Percentile Female to 75th Percentile Male) the upper and/or lower bounds for the shoulder belt passthrough will change

Height from H Point (mm)

Type of Occupant

Approx. 480mm

5th Percentile Female

Approx. 580mm

95th Percentile Male

  • Based on diagram below

[4]

Height (not including headrest): 410mm - 515mm above H Point  [6]

...