Problem Statement:

For MS15, some modules had banks with some amount of voltage difference. the highest difference was in somewhere in the range of 0.5V-0.6V. After taking apart one of the modules with a 0.5V imbalance, we found that there was a single cell in the outlier bank that was dead. We want to know what killed this cell. This Confluence page will outline our findings.

Questions to Answer:

  1. What caused the cell to die? Was it because of:

    1. Spot welding

    2. Connecting a fully charged cell to a fully discharged cell in parallel

    3. Are there any other reasons?

  2. Why is there a 0.2V imbalance between banks in some modules?

    1. Is this also caused by the dead cell, a capacity issue, or something else?

Existing Information:

  • The dead cell likely did not short, as there are 15ohms of internal resistance and the dead cell is randomly located in the module (i.e., it is not in the same/similar location between the affected modules).

  • There are no visible signs of damage to the dead cells.

  • The dead cells are severely undervoltaged and act like capacitors.

Module Voltages [*probably need to move to another page]:

The following modules are ordered from the positive terminal to the negative terminal, while the module numbers are as indicated on the orange wire bundles. The goal of checking this is to see if the parallel connections have any imbalances.

  • Module #9: 12.813V

    • 3.2696V

    • 3.2103V

    • 3.1969V

    • 3.1861V

  • Module #8: 13.129V

    • 3.2562V

    • 3.2650V

    • 3.2684V

    • 3.3429V

  • Module #7: 12.661V

    • 3.4155V

    • 3.4123V

    • 3.4132V

    • 2.4244V

  • Module #6: 12.998V

    • 3.2720V

    • 3.2380V

    • 3.2438V

    • 3.2453V

  • Module #5: 13.049V

    • 3.2630V

    • 3.2647V

    • 3.2598V

    • 3.2650V

  • Module #4: 12.991V

    • 3.2314V

    • 3.2448V

    • 3.2314V

    • 3.2875V

  • Module #3: 13.100V

    • 3.2926V

    • 3.2695V

    • 3.2691V

    • 3.2724V

  • Module #2: 13.096V

    • 3.2756V

    • 3.2751V

    • 3.2703V

    • 3.2793V

  • Module #1: 13.074V

    • 3.2546V

    • 3.2339V

    • 3.2906V

    • 3.3161V

Research:

  • If the heat is too intense or is applied for too long during spot welding, the cell can be damaged.

  • If too much pressure is applied during spot welding, the cell can be deformed, especially if its casing is thin. This can compromise the integrity of the cell.

  • If a fully charged cell were connected to a fully discharged cell, then the more likely scenario would be that both cells are damaged.

    • When such a connection is made in parallel, there will be a large current flow from the charged cell to the discharged cell in an attempt to equalize their voltages. This surge can generate excessive heat, potentially damaging both cells.

    • It is possible that the high current can cause only the discharged cell to overheat, which might lead to swelling or leakage (neither of which were noticed in the dead cells).

    • The stress from high current flow may degrade the internal chemistry of the fully charged and fully discharged cells, reducing their lifespan.

      • Maybe the dead cell was initially degraded and died later on when discharged?

      • Would be worthwhile to check if cells that are adjacent to the dead cell are performing worse than cells that are further away from the dead cell.