DCDC Validation
DCDC Validation
27-06-2023
mosfet gate and drain/source is not shorted
r8 is replaced with 10kohm resistor
30-06-2023
Testing the DCDC output with the replaced resistor (R8)
Test 1: Replaced resistor
CC (Load): 0.100A
Voltage (PSU): 60-100V
Power consumption: ~1.060W
Results:
no resistance across TR and HV GND
outputting ~10.6-10.8 volts from the range
Test 2: Removed R10
no resistance from TR to HV GND
Voltage output is slightly higher, around 10.7V at 60V input
Test 3: Replaced Q2
Same conditions: input voltage 60V
Same output voltage: ~10.7V
Suspected leg 2 of Q2 is not properly connected
when checking conductivity leg 1 & 3 were good