We tested the airflow through our prototype module, inside a cardboard tube with some 3D printed adapters, using a UNI-T UT363 BT wind speed sensor.

Pictures of our module and airflow testing rig:

Air speed measurements were taken as the average over about 1 minute (average computed on the device).

Fan Specs and Measurements:

Fan TypeVoltage (V) Current Draw (A)Power Usage (W) Rated Static Pressure (mm H2O)  Rated Airflow (CFM)Spec Link Purchase Link  Air Speed Measured (m/s)
Qualtek FAD1-12025CBMW1212 0.166 1.992 2.87 81.0 https://www.digikey.ca/product-detail/en/qualtek/FAD1-12025CBMW12/Q640-ND/2600110 https://www.digikey.ca/product-detail/en/qualtek/FAD1-12025CBMW12/Q640-ND/2600110 6.1
Noctua NF-F12 iPPC 300012 0.311 3.732 7.63 109.9https://noctua.at/en/nf-f12-industrialppc-3000-pwm/specification https://www.amazon.ca/gp/product/B00KFCRATC/ref=ppx_yo_dt_b_asin_title_o01_s00?ie=UTF8&psc=1 3.8

Calculations:

The diameter of the tube that the airspeed was measured through was 30mm.


Area of circle = (30mm / 2)2 x pi = 706.86mm2

Volume of air through module = 706.86mm2 x 6.1m/s = 15.52 m3/h

Volume of air through module = 706.86mm2 x 3.8m/s = 9.67 m3/h


Results:

FanVolume of air through module (m3/h)
Noctua NF-F12 iPPC 300015.52
 Qualtek FAD1-12025CBMW129.67