10-08-2023

Power supplied to the PD_12 and the BAT_IN

  • PD_12 supply set the 12V

  • BAT_IN set to voltages ranging from 9V to 15V

When first testing and setting the voltage to >12V, the comparator output measured around 12V. However, when turned down to <11V the output still remained high.

Restarting the test, both states produced a 0V output at the comparator.