We tested the airflow through our prototype module, inside a cardboard tube with some 3D printed adapters, using a UNI-T UT363 BT wind speed sensor.

Pictures of our module and airflow testing rig:

Air speed measurements were taken as the average over about 1 minute (average computed on the device).

Fan Specs and Measurements:

Fan TypeQualtek FAD1-12025CBMW12Noctua NF-F12 iPPC 3000
Voltage (V)1212
Current Draw (A)0.1660.311
Power Usage (W) 1.9923.732
Rated Static Pressure (mm H2O) 2.877.63
Rated Airflow (CFM)81.0109.9
Spec Link https://www.digikey.ca/product-detail/en/qualtek/FAD1-12025CBMW12/Q640-ND/2600110https://noctua.at/en/nf-f12-industrialppc-3000-pwm/specification
Purchase Link https://www.digikey.ca/product-detail/en/qualtek/FAD1-12025CBMW12/Q640-ND/2600110https://www.amazon.ca/gp/product/B00KFCRATC/ref=ppx_yo_dt_b_asin_title_o01_s00?ie=UTF8&psc=1
Air Speed Measured (m/s)3.86.1

Calculations:

The diameter of the tube that the airspeed was measured through was 30mm.


Area of circle = (30mm / 2)2 x pi = 706.86mm2

Volume of air through module = 706.86mm2 x 6.1m/s = 15.52 m3/h

Volume of air through module = 706.86mm2 x 3.8m/s = 9.67 m3/h


Results:

FanVolume of air through module (m3/h)
Noctua NF-F12 iPPC 300015.52
 Qualtek FAD1-12025CBMW129.67