This page will document all the changes for the second revision of solar sense → changes found from validation and assembly:

  • relay footprint is wrong → increase the through hole size, pad size and distance between everything so it actually mates
  • have a pin on the controller board get a high or low if connected to the right jumper config for 5 vs 6 mppt board
  • none of the vias tented?? maybe manufacturing issue (this was not jlc) but double check pcb
  • move C32 north so 12V isnt shorted to ground 😞
  • switch mosi and clock and fix miso silk (says mso)
  • reconfigure relay driver for low side output for current sinking IC
  • indicator LED for 12V
  • move the I2C pullup resistors to be near the controller board, not near the first mppt
  • Add a fan control IC for solar fan (meant to help cool nomuras inside enclosure) controlled by onboard thermistor (from 5 mppt board extra thermistor slot) and powered off of solar (will be depopped for 6 mppt solar board)
  • Also reconfigure thermistors so that the on-board resistor is a pull-up resistor and calculate the correct pull-up resistor values for the 2 types of temperature sensors - 100Ohm platinum RTD and 10K NTC thermistors
  • Add more clearance to power pads from GND pour (this may have helped the C32 12V short to gnd, its weird it did not give me a warning about that…)