MSXV full array with 5x2 MPPTs, moderate sunlight charging 36s Li-Ion pack: 130V, 2.264A

Individual Testing Dec 17, 2022

tested w protective cover on,

Open circuit voltage test

Short circuit current test

Stack 12

100 mA, 9.5 V

Stack 11

35 mA, 9.15 V

(2 halogen lamp) 10.18 V, 0.5 A

Stack 9

18.04 V, 0.42 A

Stack 11 + 9

27.88 V, 0.45 A

Testing w MPPTs

Stack 9 + 11 + 12

29.993 V, 0.163 A

5.322 Whttps://docs.google.com/spreadsheets/d/10GxkmC2_pRBlaSkuodyuwJfv6EmfgCdq5ilaQ_U7_Z8/edit?usp=sharing

Individual Panel Testing

Each MPPT was individually connected to their respective panels according to the table below.

...

The output voltage was adjusted to the target voltage, and connected to a 8p battery to confirm operation. The MPPT was considered working if the output voltage is higher than the input, and the output power was > 20% of the rated panel power (it was quite cloudy).

10 MPPTs worked, while 3 had shorted ICs

Array Testing

Two strings of 5 MPPTs were connected in series in accordance with the previous table, which were paralleled with 2 Si diodes into a 36p pack.

In moderate sunlight at about 4:30pm, the output of the whole array was 130V, 2.264A.

Given the suboptimal conditions, the power level seems to be about what is expected. The Nomura MPPTs are confirmed to be working normally.