Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

View file
nameBearing Housing Cap (FSU).zip

The Bearing Housing Cap

Expand
titlePart Details

Model Version: 8.0

Material: AISI 4130 steel, annealed at 865C

Yield Strength: 4.600e+08 Pa

Validation: June 14th, 2023 - June 15th, 2023

By: Katherine Nguyen

Table of Contents
minLevel1
maxLevel6
outlinefalse
typelist
printablefalse

Loading

Expand
titleGeneral Loading Information

Only applying Fz force

  • Only loading cases 2 and 4 are tested, since there is only one force and no moments being applied, these are the greatest magnitudes of force in both positive and negative Z

Loading Case #1:

Upright to LCA

3299.679523

2211.687897

-52.35353565

0

0

0

Loading Case #2:

Upright to LCA

-6369.683482

1976.269598

586.7106375

0

0

0

Only Fz force applied

Loading Case #3:

Upright to LCA

9264.244391

1816.545461

390.3182687

0

0

0

Loading Case #4:

Upright to LCA

-8143.498426

2526.632085

-847.4304298

0

0

0

Only Fz force applied

Loading Case #5:

Upright to LCA

11844.22222

2322.421431

-624.6421637

0

0

0

Fixtures

Mesh Refinement

Mesh Convergence & Results

Case #2: Forwards Left

Node Size

Max Stress

Location

1.5 mm

1.561e547e+07

Image RemovedImage Added

1.25 mm

1.681e570e+07

Image RemovedImage Added

 1 mm

 1.801e504e+07

 

Image Removed
Expand
titleMore pics
Image Removed
Image Added

 0.75 mm

 1.976e554e+07

 

Image RemovedImage Added

 0.5 mm

 2 1.271e563e+07 

Image AddedImage Removed
Expand
titleMore pics
Image RemovedImage RemovedImage RemovedImage RemovedImage RemovedImage AddedImage AddedImage AddedImage AddedImage Added

Case #4: Forwards Right

Node Size

Max Stress

Location

 1.5 mm

 3.391e+07

 

 1.25 mm

 3.406e+07

 

 1 mm

 3.374e+07

 

  0.75 mm

 3.401e+07

 

 0.5 mm

 3.480e+07

 

Expand
titleMore pics
Image RemovedImage RemovedImage RemovedImage RemovedImage Removed

Recommendations
Image AddedImage AddedImage AddedImage AddedImage Added

Recommendations

The bearing housing cap passed both extreme cases, with the lowest safety factor (3.59) occurring in case #4.