note there is a 4A current limit on the input power supply, because below this cannot overcome the ICLs and bulk caps

Test number: 1,2,3,4,5,6,7,8,9,10,11,12

input voltage: 90.6, 90.6, 90.6, 90.5, 130V, 130, 130, 130, 143, 143, 143, 143

...

Undervoltage lower threshold 40V upper threshold at 44V

From the above testing, the following ICL has been specced for use as a single ICL in series. Note that the decision to use a single ICL in series comes from the fact that small differences in resistance for the ICLs in parallel causes one to get much hotter than the other.

B57236S0809M000‎

B57236S0120M000‎