Date | Individual | Goals for Today | Progress/Updates | Notes and Concerns |
---|
2021-06-19 | Michael Hanley | Infusion test prep | cut 2x1 ft and 1x1 ft material | catch pot is trash, no regular cf fabric |
2021-06-24 | Mackenzie Lui | Cut vac bags/spiral tubing | Cut vac bags/spiral tubing | Found another catch pot. Old catch pot has gauge that is intact but the pot leaks. New catch pot might not be leaking but has a busted gauge. Swap the gauges? |
2021-06-25 | Renzo Villanoy | Test 3D printed connector Cut carbon fibre for testing | Prep all done | The new mold release wax has same expiry date as old one (Sep 2021) 😞 Connector tight around tube, Increase diameter by 1.5mm spiral tube 11mm diam, connector 16mm |
2021-06-29 | Kyle Lacson + Mackenzie Lui | Test Catchpot for Leaks | created vacuum bag and sealed a cf sample clamped catchpot and left it for 15 min, was able to hold pressure added soap to the catchpot (inlet and outlet) and found no bubbles pressure was constant throughout the 15 min we left it on, at around -28inHg
Image AddedImage AddedImage Added | although gage pressure was constant, when we unclamped the catchpot we heard a hissing sound at around -15inHg the tube clamps and tubes were not compatible so we had to use tacky tape to close of any gaps used the catchpot valve to clamp for 15min. Did not have a clamp strong enough or big enough to clamp the tube we used
|
2021-06-29 | Kyle Lacson + Mackenzie Lui | Drill 1/2 inch by 1/2 inch holes into the foam | Image Added | |
2021-06-29 | Kyle Lacson + Mackenzie Lui | Find buckets + stir rod for resin infusion prep | | none
|
2021-07-05 | Kyle Lacson + Mackenzie Lui | Fix catchpot pressure gauge | removed an inlet off the catchpot. Used to be 3 now it has 2 inlets. (The valve that was attached to the pressure gauge was transferred to an inlet) held a vacuum for 15min, applied soap to areas where a leak may occur. No bubbles were formed and no leaks were heard
Updated catchpot: Image Addedbefore vacuum: Image Addedvacuum applied and clamped: Image Addedafter 15 min: Image Added | pressure gauge reading is off. Reading around -10 inHg when it should start off at 0 inHg before the vacuum was applied after 15 min, pressure seemed to lower by 1inHg. tried to adjust some screws within the pressure gauge but was not able to move the needle.
|
2021-07-16 | Mackenzie Lui Kyle Lacson | Apply mold release wax to a 1ft x 1ft area on the large glass pane | Taped out a 13”x13” area with masking tape on the large glass. Follow instructions on wax can. Applied 6 coats of wax using disposable cloth. Buffed glass 1 minute after application of each wax layer (when the wax solidifies) using disposable cloth. Buff until smooth. Application/buffing technique demonstrated in Rock West video. - Image Added
| Used existing boundary outlined with masking tape for 2 sides, Wait time before buffing differs from Rock West video since they are using a different wax. Large glass pane already has Locktite residue, will tacky tape stick to the border???
|
| | | | |
| | | | |
| | | | |
| | | | |
| | | | |