The second testing will be a fully integrated test to see if the current going to the battery is sufficient for prolonged periods of time.

MPPT#Outside ConditionsResistance of E-loadVoltage on E-loadCurrent on E-loadNotes
1cloudy25025.2520.1012sun is not out will test rest later. also at a certain resistance the mppt goes into through mode, has 8w output, and when its not it has like 2W input





























































Array testing outside rear in series

This testing will be conducted when the car is on and outside, and the mppts are actively charging the battery, which will be measured by a current clamp. All the mppts from the rear panel will be connected to the main battery pack, and the array will be facing the sun. The following table summarizes the test results.


Weather/Outside conditionsCurrent Measured from array to Batteries
Notes

























Note: the car first had to fully turn on for the current path to be tested. This meant taking out the battery box and fixing one of the mppts becuase of a BMS fault that did not allow the car to shift from the aux power supply to the main battery pack.

Additional note: the car is still not working, so we are going to test it by putting 6 50W 150mohm resistors in series to get maximum power out from the mppts, and measure the current passing through the resistors in series.



TESTING OUTSIDE IN THE SUN 2 MPPTs IN SERIES

Image Added

today we are finally testing the car outside by placing a dc load in series on the output of two mppts. THe eload will be placed on the output of the two mppts, and the following table summarizes the notes. We are testing mppt labelled 2 as mppt1, and mppt labelled as 4 mppt 2.

Input Voltage mmpt1Input voltage mppt2Output voltage(oc) mppt1Output voltage(oc) mppt2Output voltageOutput VoltageEl-load voltage (oc)Output voltage e-loadOutput current on E-loadE-load settingWeatherNotes
19.8419.8426.9826.9624.61221.8953.86345.951.10841ohmsSunny outside, array is facing sun directlyoutput current is kind of jumping
19.8419.8426.9826.9626.05421.92
510.88551V
max power out from a 0.8amp current draw
















































uplaod video from testing

...

SPI Communication Testing of MPPTs

...