Thermal Failure Criteria of the Battery Box

“…we will use maximum temperature as pass/failure criteria similar to FEA simulations…” - back this up w researchThe thermal failure criteria of the battery box is defined by a maximum system operating temperature.

Info

Temperature Limit of System: 45 °C
Reaching this limit will disable regen and solar for a short time until the pack is cool.

This value was determined based on the LG MJ1 (Rechargeable Lithium-Ion Battery) Datasheet. It can be found in Appendix 1 of the ASC 2021 VDR Battery Tech Report.

...

Battery Box Cooling Requirements - ASC Regs

Image Removed

Assembly, geometry, and material properties of the battery box

...

Component

...

Material

...

Thermal Conductivity (W/ m K)

...

Specific Heat Capacity (J/kg K)

...

Mass (kg)

...

LG MJ1 18650

...

assume uniform temp within 18650s

...

830

...

41.5 (48 g* 864 cells)

...

Nickel

...

90

...

440

...

0.8

...

EMS Sigma 60

...

200

...

400

...

Acetal

...

0.3-0.37

...

1400-1500

...

Fish Paper

...

0.29

...

1687

...

PETG

...

0.29

...

1200

...

Air

...

0.025

...