https://uwmidsun.atlassian.net/browse/MH-152

J1772 Interface

  •  When board is powered, Regulator U3 should output 5V otherwise the PP and CP readings may be off.
  •  Y1 should output a 16MHz wave otherwise CAN may not work as expected.

Proximity Pilot (PP)

...

“Parallel resistance” refers to the resistors + switch on pin 5 on the connector side.

Expected readings:

EVSE_PROXIMITY Voltage Parallel Resistance (VOhms)

U4 Inverting Input Voltage (V)

PA7 Voltage (V)

Not Connected (infinite)

4.46

2.735

480

2.77

1.53938

150

1.53

0.938

  •  PA7 should always be DC. Time constant for RC filter (R8, C10) = 10us = 100kHz
  •  PA7 should never exceed 3.3V

Control Pilot (CP)

...

Status

2.77

2.77

1.938

...

EVSE_CONTROL_PILOT Voltage (V)

PA6_AN6_CONTROL_PILOT_PWM Voltage (V)

PA5_AN5_CONTROL_PILOT_SENSE Voltage (V)

A (standby)

0

0

0

B (vehicle detected)

+9/-12V square wave 1kHz

+2.87/0V square wave 1kHz

2.87 * duty cycle

C (ready)

PA2_CONTROL_PILOT_SELECT must be ON to enter this state

+6/-12V square wave 1kHz

+1.27/0V square wave 1kHz

1.27 * duty cycle

  •  PA5 should always be DC. Time constant for RC filter (

...

  • C17,

...

  • R20) t =

...

PA7 should never exceed 3.3V.

  • 0.1s = 10Hz
  •  Neither PA6 or PA5 should exceed 3.3V
  •  Duty cycle depends on maximum current allowed for charging

Relay Controls

  •  Both PB7 and PB9 should be enabled before any power is detected on 12V_CONTACTOR_COIL_SW (cathode of D9).
  •  When both are enabled, 12V_CONTACTOR_COIL_SW should be at 12V.
  •  When both are enabled, initial current should be approx 30A and LED3 should turn on. It should be enough to close the relay.
  •  The relay should open if PB7 or PB9 (or both) are off.