Testing Results


TEST SETUP:

Image Added

(It was a lot brighter than the image shows. Each lamp is a 500W halogen lamp, for 2000W total)


Below are shown the graphs produced form the tests, the tests with single panels were completed with all 4 halogen lights shining on a single panel:

Image Added

Panel Only


Image Added

1 Panel, 1 MPPT



Image Added

2 Panels, 2 MPPTs, Parallel (with regular diodes on outputs of individual MPPTs)


Image Added

2 Panels, 2 MPPTs, Series


ConditionVmpp (V)Impp (A)Pmpp (W) MPPT Power LossMPPT Efficiency 
Panel Only15.0280.82912.452

Panel With MPPT14.6380.80211.7390.713 94.3%
2 Parallel17.7270.73212.982

2 Series30.6480.4413.477