Due to the readings from testing at 70V, the testing has stopped and will be completed after placing a fan for heat sinking on top of the vicor module.



Test Results with 2.5KW DC LoadsĀ 


Voltage InputCurrent Input (Supply)Max TempOutput CurrentOutput VoltageDC Load SettingNotes
45.42.0231.75.8813.65.88A
59.84.0440.015.7113.415.71A
59.83.854117.7913.317.7A
79.63.3842.518.0513.3?the dc load is controlled by anotherĀ 
99.42.74318.113.3?
125.51.738.218.313.3?
142.11.84417.513.3
the fan takes .135Amps@12V


Note: the dcdc fan for this testing takes .135Amps@12V