Due to the readings from testing at 70V, the testing has stopped and will be completed after placing a fan for heat sinking on top of the vicor module.
Test Results with 2.5KW DC LoadsĀ
Voltage Input | Current Input (Supply) | Max Temp | Output Current | Output Voltage | DC Load Setting | Notes |
---|---|---|---|---|---|---|
45.4 | 2.02 | 31.7 | 5.88 | 13.6 | 5.88A | |
59.8 | 4.04 | 40.0 | 15.71 | 13.4 | 15.71A | |
59.8 | 3.85 | 41 | 17.79 | 13.3 | 17.7A | |
79.6 | 3.38 | 42.5 | 18.05 | 13.3 | ? | the dc load is controlled by anotherĀ |
99.4 | 2.7 | 43 | 18.1 | 13.3 | ? | |
125.5 | 1.7 | 38.2 | 18.3 | 13.3 | ? | |
142.1 | 1.8 | 44 | 17.5 | 13.3 | the fan takes .135Amps@12V |
Note: the dcdc fan for this testing takes .135Amps@12V