Voltage Input (Supply)Current input (Supply)Voltage output (Measured by 6*Vacross resistor)Current outputTime

Temperature of Heat Sink

Notes
50




It started faulting at this 50V input, so I just moved on to 70V.
70 (71)1.65 (1.72 initially)13.467.61321086degreesCIt heated up a whole lot. I stopped it after 10 minutes, but that's because I noticed the resistors started melting the plastic box they were in. The temperature of the module itself was still steadily increasing (with no foreseeable stop) at about .1degreesC/sec. I need to find a better heat sinking method before testing will be continued.
90





110





130





150






Due to the readings from testing at 70V, the testing has stopped and will be completed after placing a fan for heat sinking on top of the vicor module.