Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

IEC ampacity (A/m2)1.3cyclic load1.3alt(min)2500alt(max)2600Kx0.8








currentKt(min) (T=60C)Kt(max) (T=60C)Kt(max) (T=45C)Wire diameterCross sectional area100% cable area% cable usedKeKvKa(min)Ka(max)I(rating) maxI rating minwire current ratingmaxium fuse
Battery fuse84.663929310.8450.9
6.1529.7057220465.126099470.4561262270.9510.9750.97165.0368992144.8198791255191.25EXRAD-XLX-4X
Charger fuse21.825396830.90.90.952.588265.26145284716.788766790.3133912640.9110.9750.9742.0771097538.973922955734154.2575Awg 108
Motor fuse 140.219760770.8450.9
4.9519.244218530.938277520.6220197130.9510.9750.9778.4010931268.79695922155116.25EXRAD-XLX-6X
Motor fuse 240.219760770.8450.9
4.9519.244218530.938277520.6220197130.9510.9750.9778.4010931268.79695922155116.25EXRAD-XLX-6X
Solar fuse9.0554791380.8450.9
1.628142.0819647576.9657531830.2988858060.910.9750.9718.6326731216.350170673224Awg 14
Pre-charger fuse2.10.8450.9
1.023620.822938551.6153846150.509438150.9510.9750.974.0935672513.5921052631612Awg 18
DC DC fuse2.1244077640.8450.9
1.023620.822938551.6341598180.5035851090.9510.9750.974.1411457393.6338553861612Awg 18

...


Fusecurrent rating
battery fuseXEV25-175175
Charger fuseXEV10-40 (not ready)405050
Motor fuse 1XEV20-8080
Motor fuse 2XEV20-8080
Solar fuseXEV10-2020
Pre-charger fuseXEV10-55
DC DC fuseXEV10-55

...