The goal of cell testing:

The more data and the more informed we are about the status of our pack, the better.


What parameters can be measured, and do they cause pack imbalance?

As-Received OCV - Assuming the cells were manufactured at the same point on the voltage curve, the as-received OCV is an indicator of the amount of self-discharge current of the cell. See the self-discharge method.

Cell Weight

Ir

Im

Self-Discharge (https://literature.cdn.keysight.com/litweb/pdf/5992-2517EN.pdf?id=2911018). Keysight has developed a self-discharge measuring unit, which incorporates a super-high precision DC voltage source and a super high precision current measurement device (accurate to the tens of uA). The bucket method described in the document provides a quick test of the self-discharge current. A single cells having a significantly higher self-discharge current will cause the module to have a larger self-discharge current. Over long periods of time (such as sitting idle in the bay for a month), this self discharge current will cause an imbalance in SoC of the cells and lead to decreased pack capacity.

Capacity





Ideal situation: Test, Estimated Time Required per cell

...