- High-Side
- High immunity to ground disturbance
- The common-mode voltage tolerance of the differential op-amp must be greater than 12V
- HSD Current Mirror
- A HSD built-in current mirror with high gain plus a current sense resistor should use less power than the low-side sensing (needs proof)
- The accuracy is around +/- 30% for low current (< 100 mA)
Block Diagram