Page Properties


DescriptionHandles LV and HV power distribution
Target release
Epic

Jira Legacy
serverJIRA (uwmidsun.atlassian.net)
columnskey,summary,type,created,updated,due,assignee,reporter,priority,status,resolution
serverId6df7ba0d-c6df-39f5-b19f-bb96d235af5f
keyELEC-82

Document owner
Project leads
Team members


Open Tickets

Jira Legacy
serverSystem JIRA
columnskey,summary,type,created,assignee,reporter,priority,status,resolution
maximumIssues1000
jqlQuerykey = elec-82
serverId6df7ba0d-c6df-39f5-b19f-bb96d235af5f

Goals

  • Distribute power to all components with maximum efficiency
  • Reliable operation

...

#TitleUser StoryImportanceNotes
1DCDC ConversionConvert ~150V to 12VDC at 15Aup to 30 AMust Have
  • Isolated DCDC Module
2Thermal ControlControl temperature of the DCDC for reliable operationsMust Have
  • Heatsink
  • Fans
3Power DistributionDistribute power to all boards and powerMust Have
  • NMOSHigh Side Load Switch
4ProtectionFuse each rail on the board, as well as the inputsMust Have
  • Board mounted automotive fuse

...

QuestionOutcome
Do we want high side or low side switching?We will do low high side switching , and utilize NMOS to achieve this. using load switches. 
Will each board be ground individually? Or a star ground?Each component that we have to control will have a ground ran to a FET on chaos, this will switch the component on and offCurrently, grounds return back to power distribution. However, an alternate may be to use the chassis as ground. 
How much monitoring is required for the 12V aux battery?ASC only requires under voltage protection for the supplemental battery, more clarification is needed for WSCOnly monitoring voltage for ASC 2018. 

Not Doing

  • Charging the aux battery will no longer be handled by chaos

...