Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

According to my current calculations, each clamp can support a maximum load of around 100 N before occurring plastic deformation (which could be an incorrect result). This value is greater than the expected load a given clamp will receive. See Figure X for fixture and force setup and results.

...