Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  • zener diode taken off, and the short stopped after removing

  • testing the diode for bias, seems like the diode was the problem

25-07-2023

  • controller board is not the problem, correctly outputs 3V3 (when testing independently)

  • when the controller board is connected and the PD is supplied with a 12V, the 3V3 voltage rail is supplied ~1.8-1.9V when the controller board is connected, even the 3V3 rail on the CB is 1.8-1.9V(with test points both on the pd and cb)