The Hub Nut

...

Expand
titleGeneral Loading Information

Fx:

  • The only force that acts on the Hub Nut is along the x axis

Loading Cases

Case

Fx

1

0

2

-1080.4

3

759.92

4

-1381.27

5

971.55

...

Expand
titleMesh Info
  • h-adaptive modellingmethod, 3 timesloops, with mesh coarsening enabled

Image Added

  • The mesh was refined around the edge of the Hub Nut to ensure accurate modelling

  • the rest of the mesh was created normally