Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

The UCA

Expand
titlePart Details

Model Version: 8.0

Material: AISI 4130 steel, annealed at 865C

Yield Strength: 460 MPa

Validation: June 14th 2023

...

Expand
titleFixture Info
  • Inner diameter fixed fully

Image Added

Loading

Expand
titleGeneral Loading Information

Fx & Fy:Fz:

  • The only force that acts on the Hub Nut is along the x axis

Image Added

Loading Cases

Fz

Case

FxFy

1

0

1

22

-1080.4

3

759.92

4

-1381.27

5

971.55

Mesh

Expand
titleMesh Info
  • h-adaptive modelling, 3 times, with mesh coarsening

  • The mesh was refined around the edge of the Hub Nut to ensure accurate modelling

Image Added
  • the rest of the mesh was created normally

Image Added

Note: the mesh looks super dense at the corners and makes it take forever to simulate

Simulation Results

Case

Max Stress (MPa)

Model

1

N/A

N/A

2

40.37

Image Added

3

38.32

Image Added

4

5