Nominal forces on the hub nut body appear to be converging-ish around 0.0125 MPa
Max stress 29.47 MPa < 460 MPa → PASS
...
Max Node Size (mm) | Mesh Pictures, after h-adaptive refinement | Max Stress (MPa) | Nominal Stress (MPa) | Location/Results |
---|---|---|---|---|
5.63 2.67 (on flange edge) | 29.47 | 0.01277 | ||
4.53 2.67 (on flange edge) | 31.84 | 0.02145 | ||
3.57 2.67 (on flange edge) | 39.44 | 0.01507 | ||
3.01 2.67 (on flange edge) | 42.42 | 0.01049 |