Preliminary Checks

  • Checking shorts between 12V+ and GND

  • Check fuse

  • Low impedance on the same net

  • Impedance between HV GND and LV GND

  • HV and 12V should be open

Efficiency

  • Check input and output power

  • Sweep through the voltages (max 150V). Find out where performance is optimal and where it’s not very good

  • Check with different loads. Sweep through the different loads (Constant Current or Constant Resistant)

Discharge circuit

  • Make sure it works :)

  • Charge and discharge time of the capacitors (using a scope).

  • (Maybe include a sense resistor to step down voltage and test)

Transient Analysis

  • Measure the voltage for the Inrush Current Limiter. Use a scope to see how long it takes to reach 12V

  • Ask Strategy what they want from our validation

Audible noise

  • Should hear no noise

Heating

  • See how the board performs just with the heat sink

  • Place the fan perpendicular to the fins (air should be parallel to fins)

Fault Mode

  • Draw 18-19A of current and let it trip. Red LED should turn on

  • TODO : Read through the conditions to figure out what causes the fault

  • Overcurrent, overvoltage, overtemperature

Stress Testing

  • Run it at 150V/ <nominal current> for an hour

  • See how thermal characteristics, efficiency changes over time

  • Ensure none of the fault conditions are triggered (since we don’t trigger fault condition during the actual race)

  • Fix if something goes wrong (thumbs up)

Inrush Current

  • Specifically with the capacitors

  • Test the output one (doesn’t blow anything up)

  • Using clamp meter to measure inrush current