Due to the internal resistance of battery cells, they produce heat when a current is applied to them. We must dissipate this heat somewhere to stop the cells from heating up.
...
P-Q Curves explanation and measurement principles: http://www.arx-group.com/pq.html
P-Q Curves of some Noctua fans: https://noctua.at/en/nf-a12x25-performance-comparison-to-nf-f12-and-nf-s12a
...
We measured the airflow of our Noctua IPPC fan when pulling air through 1 or our prototype modules (see this page). We will be contacting Noctua to obtain a more accurate P-Q curve for their fan.
Condition | Airflow (m3/h) | Airflow (CFM) | Static Pressure (from Cooling Technique Testing) | Static Pressure (from Noctua P-Q Curve) |
---|---|---|---|---|
Just fan duct | 26.97 | 15.87 | 5.55 | |
1 Module and fan duct | 15.52 | 9.13 | 5.6 |
...
Variable | Description | Value (Units) |
---|---|---|
H | Least amount of heat removed | (W) |
Cp | Specific heat capacity of the air | 1005 (J/Kg℃) |
M | Mass of the air | (Kg) |
∆T | Temperature difference | Tc - Tamb (℃) |
M = Q x ρ
Variable | Description | Value |
---|---|---|
M | Mass of the air | |
Q | Flow rate of the air | |
ρ | Density of the air | ρ = 1.18 Kg/m3 |
...