Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Linked broken link back to archive.org

Due to the internal resistance of battery cells, they produce heat when a current is applied to them. We must dissipate this heat somewhere to stop the cells from heating up.

...

P-Q Curves explanation and measurement principles: http://www.arx-group.com/pq.html

P-Q Curves of some Noctua fans: https://noctua.at/en/nf-a12x25-performance-comparison-to-nf-f12-and-nf-s12a

...

We measured the airflow of our Noctua IPPC fan when pulling air through 1 or our prototype modules (see this page). We will be contacting Noctua to obtain a more accurate P-Q curve for their fan.

ConditionAirflow (m3/h) Airflow (CFM) Static Pressure (from Cooling Technique Testing) Static Pressure (from Noctua P-Q Curve)
Just fan duct26.97 15.87 5.55
1 Module and fan duct15.52 9.13 5.6

...

VariableDescriptionValue (Units)
HLeast amount of heat removed(W)
CpSpecific heat capacity of the air1005 (J/Kg℃)
MMass of the air(Kg)
∆TTemperature differenceTc - Tamb ()

M = Q x ρ

VariableDescriptionValue 
MMass of the air
QFlow rate of the air
ρDensity of the air ρ = 1.18 Kg/m3 

...