Table of Contents |
---|
...
Focused on lowering stresses for Top 30 wall case
Added a total of 12 longitudinal reinforcement tubes to try to add more resistance to bending during impact
all 1” square tubing
Testing the effects of a greater wall thickness (0.113”)
Note: there are currently interferences with floor panels, changes can be made to the reinforcement placement later
...
Stress Results
(not done yet, running into errors - some tubes were split into tiny segments?)
Max Combined Stress (MPa) | ||
Scenario | REV 2.0/3.0? ("July 1_TommyRev.wbpj") | REV5.0 |
B-Pillar | 351.49 | to do |
Side 60 | 648.65 | to do |
Top 30 | 1374.9 | to do |
Rev 5.1 - Longitudinal Tubes
...
Max Combined Stress (MPa) | ||
Scenario | Rev 0 (August 21, 2021) 2 passengers | REV5.1 2 passengers |
B-Pillar | 351 | 318 |
Side 60 | 648 | 607 |
Top 30 | 1374 | 1130780 |
Red = 200 MPa or more
B-Pillar
...
More tubes in the longitudinal direction (front to back)
Note to self:
The back bar (collision object 11) is not compiling properly
contact is red and open