The thermal failure criteria of the battery box is defined by a maximum system operating temperature.
Info |
---|
Temperature Limit of System: 45 °C |
This value was determined based on the LG MJ1 (Rechargeable Lithium-Ion Battery) Datasheet. It can be found in Appendix 1 of the ASC 2021 VDR Battery Tech Report.
...
Battery Box Cooling Requirements - ASC Regs
Assembly, geometry, and material properties of the battery box
This page summarizes materials used in the battery box and their associated thermal characteristics → Specific Heat Capacity of the Battery Pack
Also summarized below
...
Component
...
Material
...
Thermal Conductivity (W/ m K)
...
Specific Heat Capacity (J/kg K)
...
Mass (kg)
...
LG MJ1 18650
...
assume uniform temp within 18650s
...
830
...
41.5 (48 g* 864 cells)
...
Nickel
...
90
...
440
...
0.8
...
EMS Sigma 60
...
200
...
400
...
Acetal
...
0.3-0.37
...
1400-1500
...
Fish Paper
...
0.29
...
1687
...
PETG
...
0.29
...
1200
...
Air
...
0.025
...