Firmware output from the project smoke_ltc6811 with number of cells set to 24 and number of devices set to 2:

Basically, shit works!

...

From one AFE and 12 cells, here are the recorded readings (converted to volts) vs a multimeter reading:

Multimeter

AFE reading (converted to volts)

4.1251

4.1221

3.9691

3.9700

4.0708

4.0701

4.0829

4.0826

4.1287

4.1282

4.0882

4.0881

4.1330

4.1319

4.1022

4.1011

3.9746

3.9747

4.1255

4.1240

4.1178

4.1169

4.1389

4.1357